Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Validation of a novel smartphone-based photoplethysmographic method for ambulatory heart rhythm diagnostics: the
Jonatan Fernstad1,2, Emma Svennberg3, Peter Åberg1
1Karolinska Institutet, Department of Clinical Sciences, Danderyd University Hospital, Entrévägen 2, 182 88, Stockholm, Sweden.
Aims:
In the current guidelines, smartphone photoplethysmography (PPG) is not recommended for diagnosis of atrial fibrillation (AF), without a confirmatory electrocardiogram (ECG) recording. Previous validation studies have been performed under supervision in healthcare settings, with limited generalizability of the results. We aim to investigate the diagnostic performance of a smartphone-PPG method in a real-world setting, with ambulatory unsupervised smartphone-PPG recordings, compared with simultaneous ECG recordings and including patients with atrial flutter (AFL).
Methods And Results:
Unselected patients undergoing direct current cardioversion for treatment of AF or AFL were asked to perform 1-min heart rhythm recordings post-treatment, at least twice daily for 30 days at home, using an iPhone 7 smartphone running the CORAI Heart Monitor PPG application simultaneously with a single-lead ECG recording (KardiaMobile). Photoplethysmography and ECG recordings were read independently by two experienced readers. In total, 280 patients recorded 18 005 simultaneous PPG and ECG recordings. Sufficient quality for diagnosis was seen in 96.9% (PPG) vs. 95.1% (ECG) of the recordings (P < 0.001). Manual reading of the PPG recordings, compared with manually interpreted ECG recordings, had a sensitivity, specificity, and overall accuracy of 97.7%, 99.4%, and 98.9% with AFL recordings included and 99.0%, 99.7%, and 99.5%, respectively, with AFL recordings excluded.
Conclusion:
A novel smartphone-PPG method can be used by patients unsupervised at home to achieve accurate heart rhythm diagnostics of AF and AFL with very high sensitivity and specificity. This smartphone-PPG device can be used as an independent heart rhythm diagnostic device following cardioversion, without the requirement of confirmation with ECG.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring pulse