Related Experiment Video
Updated: Jun 29, 2025

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Deviation From Personalized Blood Pressure Targets Correlates With Worse Outcome After Successful Recanalization
Zhe Zhang1,2, Yuehua Pu1, Lei Yu1,3
1Neurocritical Care Unit, Department of Neurology, Beijing Tiantan Hospital Capital Medical University Beijing China.
Background:
Personalized blood pressure (BP) management for patients with acute ischemic stroke after successful endovascular thrombectomy lacks evidence. We aimed to investigate whether the deviation of BP from cerebral autoregulation limits is associated with worse outcomes.
Methods And Results:
We determined autoregulation by measuring mean velocity index and calculated the percentage of time and the burden (defined as the time-BP area) with BP outside the autoregulatory limits of each subject within 48 hours after endovascular thrombectomy. In total, 91 patients with large vessel occlusion stroke who had achieved successful recanalization were prospectively enrolled between May 2020 and February 2022. The burden with BP outside the autoregulatory limits was associated with poor outcome (modified Rankin Scale score 3-6) at 90 days (adjusted odds ratio, 1.28 [95% CI, 1.03-1.59]). The percentage of time with BP out of the autoregulatory limits was correlated with early neurological deterioration (National Institute of Health Stroke Scale scores increased ≥2 at 7 days) (adjusted odds ratio, 1.38 [95% CI, 1.04-1.83]). The burden of BP that decreased below the autoregulatory lower limit was associated with significant infarct growth (volume of infarct growth >11.6 mL) at 7 days (adjusted odds ratio, 1.21 [95% CI, 1.01-1.44]). The percentage of time that BP exceeded the autoregulatory upper limit was associated with symptomatic intracranial hemorrhage within 48 hours (adjusted odds ratio, 1.55 [95% CI, 1.02-2.34]).
Conclusions:
Both the percentage of time and the burden of BP that deviates from the autoregulation-preserved range are associated with unfavorable clinical outcomes. This study highlights the potential benefits of autoregulation-guided BP management strategy after successful recanalization.
More Related Videos
09:00Real-Time Monitoring and Modulation of Blood Pressure in a Rabbit Model of Ischemic Stroke
Published on: February 10, 2023
07:25Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)