Colorimetric CO2 Detector to Improve Effective Mask Ventilations in Very Preterm Infants: A Pilot Randomized
Juin Yee Kong1,2,3,4, Bin Huey Quek1,2,3,4, Charis S E Lim1
1Department of Neonatology, KK Women's and Children's Hospital, Singapore, Singapore.
Introduction:
End-tidal CO2 (ETCO2) detector is currently recommended for confirmation of endotracheal tube placement during neonatal resuscitation. Whether it is feasible to use ETCO2 detectors during mask ventilation to reduce risk of bradycardia and desaturations, which are associated with increased risk of death in preterm babies, is unknown.
Methods:
This is a pilot randomized controlled trial (NCT04287907) involving newborns 24 + 0/7 to 32 + 0/7 weeks gestation who required mask ventilation at birth. Infants were randomized into groups with or without colorimetric ETCO2 detectors. Combined duration of any bradycardia (<100 bpm) and time below prespecified target oxygen saturation (SpO2) as measured by pulse oximetry were compared.
Results:
Fifty participants were randomized, 47 with outcomes analysed (2 incomplete data, 1 postnatal diagnosis of trachea-oesophageal fistula). Mean gestational age and birthweight were 28.5 ± 1.9 versus 29.4 ± 1.6 weeks (p = 0.1) and 1,252.7 ± 409.7 g versus 1,334.6 ± 369.1 g (p = 0.5) in the intervention and control arm, respectively. Mean combined duration of bradycardia and desaturation was 276.7 ± 197.7 s (intervention) and 322.7 ± 277.7 s (control) (p = 0.6). Proportion of participants with any bradycardia or desaturation at 5 min were 38.1% (intervention) and 56.5% (control) (p = 0.2). No chest compressions, epinephrine administration, or death occurred in the delivery room.
Conclusion:
This pilot study demonstrates the feasibility of a trial to evaluate colorimetric ETCO2 detectors during mask ventilation of very preterm infants to reduce bradycardia and low SpO2. Further assessment with a larger population will be required to determine if ETCO2 detector usage at resuscitation reduces risk of adverse outcomes, including death and disability, in very preterm infants.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...