The Assessment of a Novel Endoscopic Ultrasound-Compatible Cryocatheter to Ablate Pancreatic Cancer
John M Baust1,2, Anthony Robilotto1, Isaac Raijman3,4
1CPSI Biotech, Owego, NY 13827, USA.
Abstract:
Pancreatic ductal adenocarcinoma (PDAC) is a highly lethal disease that may be treated utilizing thermal therapies. Cryoablation is an effective, minimally invasive therapy that has been utilized for the treatment of various cancers, offering patients a quicker recovery and reduced side effects. Cryoablation has been utilized on a limited basis for the treatment of PDAC. With the recent reports on the success of cryoablation, there is a growing interest in the use of cryoablation as a standalone, minimally invasive procedure to treat PDAC. While offering a promising path, the application of cryoablation to PDAC is limited by current technologies. As such, there is a need for the development of new devices to support advanced treatment strategies for PDAC. To this end, this study investigated the performance of a new endoscopic ultrasound-compatible cryoablation catheter technology, FrostBite. We hypothesized that FrostBite would enable the rapid, effective, minimally invasive delivery of ultra-cold temperatures to target tissues, resulting in effective ablation via an endoscopic approach. Thermal properties and ablative efficacy were evaluated using a heat-loaded gel model, tissue-engineered models (TEMs), and an initial in vivo porcine study. Freeze protocols evaluated included single and repeat 3 and 5 min applications. Isotherm assessment revealed the generation of a 2.2 cm diameter frozen mass with the -20 °C isotherm reaching a diameter of 1.5 cm following a single 5 min freeze. TEM studies revealed the achievement of temperatures ≤ -20 °C at a diameter of 1.9 cm after a 5 min freeze. Fluorescent imaging conducted 24 h post-thaw demonstrated a uniformly shaped ellipsoidal ablative zone with a midline diameter of 2.5 cm, resulting in a total ablative volume of 6.9 cm3 after a single 5 min freeze. In vivo findings consistently demonstrated the generation of ablative areas measuring 2.03 cm × 3.2 cm. These studies demonstrate the potential of the FrostBite cryocatheter as an endoscopic ultrasound-based treatment option. The data suggest that FrostBite may provide for the rapid, effective, controllable freezing of cancerous pancreatic and liver tissues. This ablative power also offers the potential of improved safety margins via the minimally invasive nature of an endoscopic ultrasound-based approach or natural orifice transluminal endoscopic surgery (NOTES)-based approach. The results of this pre-clinical feasibility study show promise, affirming the need for further investigation into the potential of the FrostBite cryocatheter as an advanced, minimally invasive cryoablative technology.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Procedures V: ERCP
Patient...