Related Experiment Video
Updated: Jun 29, 2025

Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Degradation of RC Columns under Combined Exposure to Axial Loading, Stray Currents, and Chloride Ingress
Igor Lapiro1, Rami Eid2, Konstantin Kovler1
1National Building Research Institute, Faculty of Civil and Environmental Engineering, Technion-Israel Institute of Technology, Haifa 3200003, Israel.
Abstract:
Coastal regions, home to a significant portion of the world's population, confront a formidable challenge: the corrosive impact of chloride-rich environments on vital infrastructure. These areas often host essential transportation systems, such as trains and metros, reliant on pre-existing electrical infrastructure. Unfortunately, complete isolation of this infrastructure is rarely feasible, resulting in the emergence of stray currents and electrical potentials that expedite corrosion processes. When coupled with conducive mediums facilitating chemical electrocell formation, the corrosion of reinforced concrete elements accelerates significantly. To combat this issue, international standards have been established, primarily focusing on augmenting the thickness of reinforcement bar covers and restricting stray voltage between rails and the ground. Nevertheless, these measures only provide partial solutions. When subjected to service loads, these elements develop cracks, especially when exposed to stray currents and chlorides, dramatically increasing corrosion rates. Corrosion products, which expand in volume compared to steel, exert internal forces that widen cracks, hastening the deterioration of structural elements. The study deals with the degradation of reinforced concrete columns under the combined action of loads, chloride-rich environments, and electrical voltage-simulating stray currents. In these conditions, degradation and reduction of load-bearing capacity accelerate compared to unloaded conditions, significantly amplifying the corrosion rate. Astonishingly, even in the absence of mechanical loads, stray currents alone induce tensile stresses in elements due to corrosion product formation, leading to longitudinal cracks parallel to the reinforcement bars.
Related Concept Videos
Effects of Creep
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Columns under an Eccentric Load
Creep in Concrete
Eccentric Loading