Related Experiment Video
Updated: Jun 29, 2025

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
A Simple and Safe Method for Checking the Position of Central Venous Catheters-A New and Reliable Threshold for Right
Lukas Ley1,2, Hossein Ardeschir Ghofrani3, Pascal Klingenberger4
1Campus Kerckhoff, Justus-Liebig-University Giessen, 61231 Bad Nauheim, Germany.
Abstract:
Background: Central venous catheters (CVCs) are indispensable tools in intensive care and emergency medicine. CVC malpositions still occur frequently and can cause various complications leading to increased patient mortality. A microbubbles test (MBT) can be used to confirm correct CVC positioning. However, there is serious doubt regarding whether the currently applied threshold of a 2 s push-to-bubbles time (PTB time) for rapid atrial swirl sign (RASS) in an MBT is reliable and accurate. The aim of the present study was to prove the quality of a new threshold: 1 s. Methods: Consecutive patients who were admitted to the intensive care unit (ICU) in a German neurological specialist hospital from 1 March 2021 to 20 July 2022 were enrolled. After ultrasound-guided CVC insertion, an MBT was performed, PTB time was measured, and RASS was interpreted. Additionally, a chest X-ray (CXR) was requested to check CVC position. Results: A total of 102 CVCs (98% jugular and 2% subclavian) were inserted in 102 patients (38% female and 62% male; median age: 66 years). Negative RASS (PTB time > 1 s) was observed in 2 out of 102 patients, resulting in an echocardiographic malposition rate of 2.0%. CXR confirmed the echocardiographic results. After correcting CVC position in the initially malpositioned CVCs, the PTB time was <1 s (positive RASS). The MBT protocol took about 0.5 min on average, while the CXR results were all available within 30 min. Sensitivity, specificity, and positive and negative predictive value were each 100% for the detection of CVC malpositions via an MBT using a threshold of 1 s compared to CXR. Conclusions: A new threshold of a 1 s PTB time for RASS in an MBT could detect CVC malpositions with excellent quality compared to CXR. Since the MBT was fast and safe and could be performed at the bedside, we propose that an MBT with the new and reliable threshold of 1 s should be routinely used in patient care.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
08:51Multiple Intravenous Bolus Dosing and Invasive Hemodynamic Assessment in a Hypoxia-Induced Mouse Pulmonary Artery Hypertension Model
Published on: November 11, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...