Impact of implantation depth and calcium burden on infranodal conduction delay after transcatheter aortic valve

Andrea Papa1, Teodor Serban1, Ivo Strebel1

  • 1Department of Cardiology and Cardiovascular Research Institute Basel, University Hospital Basel, University of Basel, Basel, Switzerland.

Heart Rhythm O2
|March 28, 2024
PubMed

Insights

Calcium in the non-coronary sinus (LVOTNCC) predicts conduction delays after transcatheter aortic valve replacement (TAVR). Implantation depth does not predict these common post-TAVR complications.

Area of Science:

  • Cardiology
  • Interventional Cardiology
  • Cardiac Electrophysiology

Background:

  • Infranodal conduction disorders frequently occur after transcatheter aortic valve replacement (TAVR).
  • The precise risk factors contributing to these conduction abnormalities remain incompletely understood.

Purpose of the Study:

  • To investigate the influence of valve implantation depth and the calcium burden in the device landing zone on infranodal conduction.
  • To assess pre- and post-TAVR His-ventricle (HV) intervals to understand conduction changes.

Main Methods:

  • Measured His-ventricle (HV) interval pre- and post-TAVR in 101 patients.
  • Defined infranodal conduction delay as HV interval >55 ms.
  • Quantified valve implantation depth and calcium volume in specific aortic regions, including the left ventricular outflow tract (LVOTNCC).

Main Results:

  • 37% of patients experienced infranodal conduction delay post-TAVR.
  • No correlation was found between implantation depth or overall calcium burden and the change in HV interval (delta HV).
  • Calcification in the LVOTNCC region was a significant predictor of infranodal conduction delay (OR 1.62 per 100 mm³ increase, P = .04).

Conclusions:

  • LVOTNCC calcification is a key predictor of infranodal conduction delay following TAVR.
  • Valve implantation depth does not appear to influence the risk of developing conduction delays.
Abstract