Related Experiment Video
Updated: May 6, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
[Technical exploration and early results of two-port total thoracoscopic aortic-mitral double-valve replacement]
1Department of Cardiovascular Surgery, Fujian Medical University Union Hospital, Fuzhou 350000, China.
Abstract:
Objective: To examine the clinical outcomes of patients undergoing total thoracoscopic aortic-mitral double-valve replacement. Methods: This is a retrospective case series study. The clinical data of 50 patients who underwent double-valve replacement under a total thoracoscopic two-port approach from November 2021 to August 2022 in the Department of Cardiovascular Surgery, Fujian Medical University Union Hospital were retrospectively analyzed. There were 32 males and 18 females, with an age of (55.3±8.8) years (range: 21 to 62 years). Among them, 36 cases had rheumatic heart disease and 14 cases had infective endocarditis. The 3rd intercostal space between the right anterior axillary line and the midclavicular line was selected as the main operating hole, the total thoracoscopic double-valve replacement were successfully carried out. Baseline data, intraoperative information, surgical outcomes, and postoperative complications were collected for all patients. Results: The cardiopulmonary bypass time was (168.2±30.9) minutes (range: 125 to 187 minutes), the aortic cross-clamping time was (118.8±16.5) minutes (range: 96 to 147 minutes). Five patients received bioprosthetic valves, and 45 received mechanical prosthetic valves. Postoperative mechanical ventilation lasted (9.6±3.4) hours (range: 5.1 to 14.2 hours), the ICU stay was (24.8±7.3) hours (range: 16.3 to 30.1 hours), and the postoperative hospital stay was (6.5±1.2) days (range: 5.0 to 8.0 days). Four patients received red blood cell transfusions of (2.7±0.9) units (range: 2 to 4 units), and the postoperative chest drainage volume was (222.1±56.3) ml (range: 175 to 289 ml). No deaths occurred intraoperatively or in the early postoperative period. One patient required reoperation due to bleeding in the aortic incision. Three patients had mild to moderate paravalvular leakage around the prosthetic aortic valve, with no cases of third-degree atrioventricular block or conversions to median sternotomy. Conclusions: The early outcomes of total thoracoscopic double valve replacement surgery are satisfactory, demonstrating safety and efficacy. This surgical approach expands the scope of total thoracoscopic cardiac surgery, which warrants further investigation and research.
More Related Videos
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Stenosis III: Medical Management