Development of beat-by-beat blood pressure monitoring device and nocturnal sec-surge detection algorithm
Ayako Kokubo1, Mitsuo Kuwabara1,2, Naoko Tomitani2
1Omron Healthcare Co., Ltd., Kyoto, Japan.
Abstract:
The nocturnal blood pressure (BP) surge in seconds (sec-surge) is defined as a brief, acute transient BP elevation over several tens of seconds, triggered by obstructive sleep apnea (OSA) and sympathetic hyperactivity. Sec-surge imposes a significant strain on the cardiovascular system, potentially triggering cardiovascular events. Quantitative evaluation of sec-surge level could be valuable in assessing cardiovascular risks. To accurately measure the detailed sec-surge, including its shape as BP rises and falls, we developed a beat-by-beat (BbB) BP monitoring device using tonometry. In addition, we developed an automatic sec-surge detection algorithm to help identify sec-surge cases in the overnight BbB BP data. The device and algorithm successfully detected sec-surges in patients with OSA. Our results demonstrated that sec-surge was associated with left ventricular hypertrophy and arterial stiffness independently of nocturnal BP level or variability. Sec-surge would be worth monitoring for assessing cardiovascular risks, in addition to nocturnal BP level. Nocturnal blood pressure (BP) surge in seconds (sec-surge) places heavy load on the cardiovascular system and can trigger cardiovascular events. To identify sec-surges, we developed a beat-by-beat BP monitoring device and a sec-surge detection algorithm. Furthermore, sec-surge was more related to cardiovascular risks than conventional nocturnal BP parameters.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.