Related Experiment Video
Updated: Jun 29, 2025

Author Spotlight: Modeling an Aspect of Preeclampsia in Female Mice Using Hypoxic Human Placenta-Derived Small Extracellular Vesicles
Published on: January 26, 2024
Accuracy of Maternal Self-Report of Recent Preeclampsia Among Healthy Women
Jennifer J Stuart1,2, Geraldine Skurnik3, Andrea T Roche3
1Division of Women's Health, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Background: Preeclampsia history signals a higher risk for cardiovascular disease, but its value as a risk marker relies primarily on self-report. To identify the accuracy of maternal self-reports of recent preeclampsia, we conducted a validation study among women recruited to a web-based trial. Methods: Women with preeclampsia in the past 5 years were recruited to Heart Health 4 Moms. Preeclampsia was self-reported through an online recruitment questionnaire and affirmed via phone screen. Accuracy of maternal self-report was quantified using positive predictive value (PPV) versus medical record evidence of preeclampsia using three definitions: (1) documentation of clinician diagnosis, (2) American College of Obstetricians and Gynecologists (ACOG) 2002 diagnostic criteria (gestational hypertension and proteinuria), and (3) ACOG 2013 diagnostic criteria (gestational hypertension and proteinuria or systemic symptoms). Results: Complete medical records were received for 290 women who delivered from 2011 to 2016 and were predominantly non-Hispanic White (81.7%) with a mean age of 31.2 ± 4.8 years. Mean length of recall was 13.6 ± 14.7 months. The majority of women (92.1%) had medical record evidence of preeclampsia using ≥1 of the definitions. Maternal self-report of preeclampsia was validated for 88.3% based on clinician diagnosis, 59.0% with ACOG 2002, and 65.2% with ACOG 2013. Conclusions: In this validation study of U.S. women, the majority accurately self-reported their preeclampsia diagnosis based on medical record review. A higher proportion of self-reports validated by clinician diagnosis than ACOG criteria, suggesting women remember the diagnosis given by their provider and providers may not always follow or document criteria when making a diagnosis.
Background: Preeclampsia history signals a higher risk for cardiovascular disease, but its value as a risk marker relies primarily on self-report. To identify the accuracy of maternal self-reports of recent preeclampsia, we conducted a validation study among women recruited to a web-based trial. Methods: Women with preeclampsia in the past 5 years were recruited to Heart Health 4 Moms. Preeclampsia was self-reported through an online recruitment questionnaire and affirmed via phone screen. Accuracy of maternal self-report was quantified using positive predictive value (PPV) versus medical record evidence of preeclampsia using three definitions: (1) documentation of clinician diagnosis, (2) American College of Obstetricians and Gynecologists (ACOG) 2002 diagnostic criteria (gestational hypertension and proteinuria), and (3) ACOG 2013 diagnostic criteria (gestational hypertension and proteinuria or systemic symptoms). Results: Complete medical records were received for 290 women who delivered from 2011 to 2016 and were predominantly non-Hispanic White (81.7%) with a mean age of 31.2 ± 4.8 years. Mean length of recall was 13.6 ± 14.7 months. The majority of women (92.1%) had medical record evidence of preeclampsia using ≥1 of the definitions. Maternal self-report of preeclampsia was validated for 88.3% based on clinician diagnosis, 59.0% with ACOG 2002, and 65.2% with ACOG 2013. Conclusions: In this validation study of U.S. women, the majority accurately self-reported their preeclampsia diagnosis based on medical record review. A higher proportion of self-reports validated by clinician diagnosis than ACOG criteria, suggesting women remember the diagnosis given by their provider and providers may not always follow or document criteria when making a diagnosis.
More Related Videos
12:17The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
06:39Using a Murine Model of Psychosocial Stress in Pregnancy as a Translationally Relevant Paradigm for Psychiatric Disorders in Mothers and Infants
Published on: June 13, 2021
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...