Related Experiment Video
Updated: Jun 23, 2026

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
Published on: May 11, 2020
Analysis of guide wire displacement in robot-assisted spinal pedicle screw implantation
Qing Liu1, RuiYang Wang1, Neng Ru2
1Orthopedics Department, The First College of Clinical Medical Science, China Three Gorges University, Yichang, China.
Abstract:
Robot-assisted pedicle screw placement is prone to guide wire migration, and the related influencing factors have not yet been discussed. Therefore, this study aimed to investigate and analyze the causes of robot-assisted spinal pedicle guide wire displacement and summarize the relevant treatment strategies. The surgical outcomes of 82 patients who underwent robotic-assisted pedicle screw spinal placement at our hospital between July 2022 and June 2023 were retrospectively analyzed. A total of 342 screws were placed in 82 patients; 47 guide wires were offset, 47 guide wires were replaced, and 295 guide wires were not significantly offset, with a first guide wire offset rate of 13.7% and a total guide wire offset rate of 12.1%. Univariate analysis showed that Screw placement level, whether respiration was controlled during guide wire placement, Hu value of CT, the position of needle insertion point, and operation time had a significant effect on guide wire deviation (P < 0.05). Multivariate logistic regression analysis showed that the inclusion of screw placement segments, whether breathing was controlled during guide wire placement, and Hu value of CT had a significant effect on guide wire offset (P < 0.05). Whether the guide wire was offset had no significant effect on the accuracy of subsequent pedicle screw implantation (P > 0.05). The level of screw placement, whether breathing was controlled during guide wire placement, and Hu value of CT were independent risk factors for guide wire deviation. When causing an excursion, screw orientation can be adjusted during intraoperative screw placement, and guide wire excursion has no significant impact on the accuracy of subsequent pedicle screw placement.
Related Concept Videos
Machines: Problem Solving II
Cable Subjected to a Distributed Load
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis - Acceleration
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...