Related Experiment Video
Updated: Jun 29, 2025

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Novel fluorescent probes based on sulfur and nitrogen co-doped carbon dots for determination of three N-substituted
Galal Magdy1, Noura Said2, Ramadan A El-Domany3
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Kafrelsheikh University, Kafrelsheikh, P.O. Box 33511, Egypt; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura National University, Gamasa, 7731168, Egypt.
Abstract:
In the current work, sulfur and nitrogen co-doped carbon dots (S,N-CDs) as simple, sensitive, and selective turn-off fluorescent nanosensors were utilized for analysis of three phenothiazine derivatives, including acetophenazine (APZ), chlorpromazine (CPH), and promethazine (PZH). S,N-CDs were synthesized through a green one-pot microwave-assisted technique using widely available precursors (thiourea and ascorbic acid). HRTEM, EDX, FTIR spectroscopy, UV-Vis absorption spectroscopy, and fluorescence spectroscopy were used to characterize the as-synthesized CDs. When excited at 330 nm, the carbon dots produced a maximum emission peak at 410 nm. The cited drugs statically quenched the S,N-CDs fluorescence as revealed by the Stern-Volmer equation. The current method represents the first spectrofluorimetric approach for the determination of the studied drugs without the need for chemical derivatization or harsh reaction conditions. The importance of the proposed work is magnified as the cited drugs do not have any fluorescent properties. The fluorescence of the developed sensor exhibited a linear response to APZ, CPH, and PZH in the concentration ranges of 5.0-100.0, 10.0-100.0, and 10.0-200.0 μM with detection limits of 1.53, 1.66, and 2.47 μM, respectively. The developed fluorescent probes have the advantages of rapidity and selectivity for APZ, CPH, and PZH analysis in tablets with acceptable % recoveries of (98.06-101.66 %). Evaluation of the method's greenness was performed using the Complementary Green Analytical Procedure Index (ComplexGAPI) and Analytical GREEnness metric (AGREE) metrics, indicating that the method is environmentally friendly. Validation of the proposed method was performed according to ICHQ2 (R1) guidelines.
More Related Videos
Related Concept Videos
NMR Spectroscopy of Benzene Derivatives
Electrophilic Aromatic Substitution: Nitration of Benzene
Diazonium Group Substitution: –OH and –H
Nucleophilic Aromatic Substitution of Aryldiazonium Salts: Aromatic SN1
In the Sandmeyer reaction, for example, the diazonio group is replaced by a chloro, bromo,...
Diazonium Group Substitution with Halogens and Cyanide: Sandmeyer and Schiemann Reactions
Nomenclature of Aryl and Heterocyclic Amines

