Michael D Han1, Sterling Gray2, Emilie Dosoudil2
1Associate Professor, Department of Oral and Maxillofacial Surgery, University of Illinois Chicago College of Dentistry, Chicago, IL.
Background:
Segmental maxillary osteotomies require precise occlusal control due to variability in individual segment positioning. The role of maxillomandibular fixation (MMF) technique on occlusal control has not been validated.
Purpose:
The purpose is to measure and compare the accuracy of occlusal positioning among MMF techniques.
Study Design, Setting, Sample:
This was a double-blinded in vitro study on experiment models to simulate a 3-piece LeFort I osteotomy. The models were constricted posteriorly and expanded using 3 different MMF techniques and compared to the unaltered baseline occlusion. Based on sample size calculation, 32 separate attempts were made for each MMF technique.
Predictor Variable:
The predictor variable was MMF technique (brackets, MMF screws, and embrasure wires).
Main Outcome Variables:
The primary outcome variable was the visual occlusal analysis score, a 1.00 to 4.00 continuous scale measuring the similarity of the achieved occlusion to the planned (control) occlusion assessed by an oral and maxillofacial surgeon and an orthodontist. High visual occlusal analysis score indicated greater occlusal accuracy, with 3.50 defined as the threshold for accuracy. The secondary outcome variable was the linear error of the achieved occlusion at the canine and first molar teeth, with lower error indicating greater accuracy. An a priori accuracy threshold of 0.5 mm was set for this variable.
Covariates:
None.
Analyses:
Kruskal-Wallis test with post hoc testing was used to analyze the difference in the outcome variables of interest. P value < .05 was considered statistically significant.
Results:
Thirty-two attempts for each technique showed that brackets had higher VAOS than MMF screws and embrasure wires (median differences 1.49 and 0.48, P < .001), and had lower linear occlusal error (median differences 0.35 to 0.99 mm, P < .001).
Conclusion And Relevance:
MMF technique influences the quality of occlusal control, with greater visual rating scores and lower linear errors seen with brackets than with embrasure wires or MMF screws.