Related Experiment Video
Updated: Jun 14, 2026

EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples
Published on: March 28, 2015
Quantification and Potential Viability of Human Noroviruses in Final Effluent from Wastewater Treatment Works in
V V Mabasa1, W B van Zyl1,2, M B Taylor1
1Department of Medical Virology, Faculty of Health Sciences, University of Pretoria, Private Bag X323, Gezina, Pretoria, 0031, South Africa.
Abstract:
Growing global concerns over water scarcity, worsened by climate change, drive wastewater reclamation efforts. Inadequately treated wastewater presents significant public health risks. Previous studies in South Africa (SA) have reported high norovirus levels in final effluent and sewage-polluted surface water, indicating pathogen removal inefficiency. However, the viability of these virions was not explored. This study assessed human norovirus viability in final effluent from wastewater treatment works (WWTWs) in Pretoria, SA. Between June 2018 and August 2020, 200 samples were collected from two WWTWs, including raw sewage and final effluent. Norovirus concentrations were determined using in-house RNA standards. Viability of noroviruses in final effluent was assessed using viability RT-qPCR (vPCR) with PMAxx™-Triton X-100. There was no significant difference in GI concentrations between raw sewage (p = 0.5663) and final effluent (p = 0.4035) samples at WWTW1 and WWTW2. WWTW1 had significantly higher GII concentrations in raw sewage (p < 0.001) compared to WWTW2. No clear seasonal pattern was observed in norovirus concentrations. At WWTW1, 50% (7/14) of GI- and 64.9% (24/37) of GII-positive final effluent samples had no quantifiable RNA after vPCR. At WWTW2, the majority (92.6%, 25/27) of GII-positive final effluent samples showed a 100% RNA reduction post vPCR. PMAxx™-Triton X-100 vPCR provides a more accurate reflection of discharge of potentially viable noroviruses in the environment than standard RT-qPCR. Despite significant reductions in potentially viable noroviruses after wastewater treatment, the levels of potentially viable viruses in final effluent are still of concern due to the high initial load and low infectious dose of noroviruses.
More Related Videos
12:32EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. Part III. Virus Detection by RT-qPCR
Published on: January 16, 2016
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
Related Concept Videos
Microbial Wastewater Treatment
Biological Treatment of Effluent and Waste Water