Correlation Between ImageJ and Conventional Manual Scoring Methods for Programmed Death-Ligand 1
Rand Suleiman Al Taher1,2, Manal A Abbas1,3, Khalid Halahleh4
1Department of Medical Laboratory Sciences, Faculty of Allied Medical Sciences, Al-Ahliyya Amman University, Amman, Jordan.
Technology in Cancer Research & Treatment
|April 2, 2024
Summary
ImageJ software can reliably score programmed cell death-ligand 1 (PD-L1) in homogeneous tumor tissues. However, for heterogeneous tissues, manual scoring remains more accurate than ImageJ analysis.
Area of Science:
- Oncology
- Pathology
- Biotechnology
Background:
- Immunohistochemistry (IHC) is a key method for quantifying programmed cell death-ligand 1 (PD-L1) expression in tumors.
- Accurate PD-L1 quantification can predict patient response to cancer immunotherapies like anti-PD1/PD-L1 agents.
Purpose of the Study:
- To evaluate the efficacy of ImageJ software in scoring PD-L1 expression via IHC.
- To compare ImageJ scoring results with the conventional manual method across different tissue types and imaging parameters.
Main Methods:
- ImageJ software was employed to analyze IHC-stained tissue sections for PD-L1 expression.
- ImageJ scoring was performed using different color space options (RGB, HSB, Brightness/Contrast) and magnifications (20x, 40x).
- ImageJ results were compared against scores from the conventional manual method and between camera-captured and whole slide images.
Main Results:
- ImageJ provided comparable scores to manual methods for homogeneous tissues (diffuse large B cell lymphoma) using RGB or Brightness/Contrast settings.
- Significant discrepancies were observed between ImageJ (HSB) and manual scoring for both homogeneous and heterogeneous tissues (head and neck squamous cell carcinoma).
- ImageJ analysis showed variations based on magnification and image acquisition method (camera vs. scanner).
Conclusions:
- ImageJ is a suitable tool for scoring PD-L1 in homogeneous tumor tissues.
- For heterogeneous tumor tissues, the conventional manual scoring method is recommended over ImageJ due to potential inaccuracies.
- Image acquisition parameters significantly influence ImageJ scoring outcomes.