In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
3.0T magnetic resonance imaging-based hip bone models for femoroacetabular impingement syndrome are equivalent to
Alexander C Newhouse1, Thomas D Alter1, Lyla A Handoklow1,2
1Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA.
Abstract:
This study aimed to compare three-dimensional (3D) proximal femoral and acetabular surface models generated from 3.0T magnetic resonance imaging (MRI) to the clinical gold standard of computed tomography (CT). Ten intact fresh-frozen cadaveric hips underwent CT and 3.0T MRI scans. The CT- and MRI-based segmented models were superimposed using a validated 3D-3D registration volume-merge method to compare them. The least surface-to-surface distance between the models was calculated by a point-to-surface calculation algorithm using a custom-written program. The variables of interest were the signed and absolute surface-to-surface distance between the paired bone models. One-sample t-tests were performed using a signed and absolute test value of 0.16 mm and 0.37 mm, respectively, based on a previous study that validated 1.5T MRI bone models by comparison with CT bone models. For the femur, the average signed and absolute surface-to-surface distance was 0.18 ± 0.09 mm and 0.30 ± 0.06 mm, respectively. There was no difference in the signed surface-to-surface distance and the 0.16 mm test value (t = 0.650, p = 0.532). However, the absolute surface-to-surface difference was less than the 0.37 mm test value (t = -4.025, p = 0.003). For the acetabulum, the average signed and absolute surface-to-surface distance was -0.06 ± 0.06 mm and 0.26 ± 0.04 mm, respectively. The signed (t = -12.569, p < 0.001) and absolute (t = -8.688, p < 0.001) surface-to-surface difference were less than the 0.16 mm and 0.37 mm test values, respectively. Our data shows that 3.0T MRI bone models are more similar to CT bone models than previously validated 1.5T MRI bone models. This is likely due to the higher resolution of the 3T data.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography