Related Experiment Video
Updated: Jun 29, 2025

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Performances and determinants of proficiency testing in clinical laboratory services at comprehensive specialized
Negesse Cherie1, Teshiwal Deress2, Maereg Wolde3
1Department of Quality Assurance and Laboratory Management, School of Biomedical and Laboratory Sciences, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia. negessecherie45@gmail.com.
Abstract:
Proficiency testing (PT) is an impartial laboratory performance-evaluating system using an independent body. It is a mandatory accreditation requirement and means for improving the laboratory's performance. The study aimed to evaluate the performance of PT, with a focus on identifying and discussing determinants that influence PT performance at comprehensive specialized hospitals in northwest Ethiopia. A retrospective cross-sectional study was carried out from 2020 to 2022. Using a convenient sampling technique, laboratory tests with recorded PT results in each hospital laboratory were included. A data collection template and customized checklists were used to collect the data. Epi Data Version 3.1 for data entry and STATA Version 14.1 for cleaning and analysis were used. Binary logistic regression analyses were used. Variables with p < 0.05 in the multivariable logistic regression were considered to be statistically significant. Over nine cycles, 3807 PT challenges were distributed. The total failure rate of the laboratories was 32.4%, with a peak failure rate of 40.3% in 2020, after which the failure rate was decline to 20.6% in 2022. Among the five laboratory sections, molecular biology had the lowest failure rate (22.2%), while microbiology had the highest failure rate (56.5%). Multivariate logistic regression revealed that PT results reported without appropriate unit of measurement (AOR 7.5), lack of corrective action for PT nonconformance (AOR 7.1), and reagent unavailability (AOR 6.1) had significant effects on PT performance (p < 0.001). The results of this study showed that the overall performance of the laboratory was lower. Reporting PT results without appropriate units of measurement and not taking corrective action for PT nonconformance were the major aggravating factors for high failure rates.
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Pneumonia III: Complications and Assessment
Interdisciplinary Care: The Health Care Team-II
Physical Therapist
A physical therapist (PT) aims to restore function or prevent additional impairment in a patient following an injury or disease. Massage, heat, cold, water, sonar waves, exercises, and electrical stimulation are some treatments used by PTs to treat...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...