Related Experiment Video
Updated: Jun 29, 2025

Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
Published on: July 18, 2015
Optimal sizing and power losses reduction of photovoltaic systems using PSO and LCL filters
Mohammed F Elnaggar1,2, Armel Duvalier Péné3,4, André Boussaibo3
1Department of Electrical Engineering, College of Engineering, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia.
Abstract:
The integration of renewable energy systems into electricity grids is a solution for strengthening electricity distribution networks (SEDNs). Renewable energies such as solar photovoltaics are suitable for reinforcing a low-voltage line by offering an electrical energy storage system. However, the integration of photovoltaic systems can lead to problems of harmonic distortion due to the presence of direct current or non-linear feedback in networks from other sources. Therefore, connection standards exist to ensure the quality of the energy before injection at a point of common coupling (PCC). In this work, particle swarm optimization (PSO) is used to control a boost converter and to evaluate the power losses and the harmonic distortion rate. The test on the IEEE 14 bus standard makes it possible to determine the allocation or integration nodes for other sources such as biomass, wind or hydrogen generators, in order to limit the impact of harmonic disturbances (LIHs). The evaluation of the harmonic distortion rate, the power losses as well as the determination of the system size is done using an objective function defined based on the integration and optimization constraints of the system. The proposed model performs better since the grid current and voltage are stabilized in phase after the photovoltaic source is injected.
More Related Videos
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
09:19In Situ Monitoring of the Accelerated Performance Degradation of Solar Cells and Modules: A Case Study for CuIn,GaSe2 Solar Cells
Published on: October 3, 2018
Related Concept Videos
Power Factor Correction
Maximum Power Flow and Line Loadability
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Fast Decoupled and DC Powerflow
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
The Power Flow Problem and Solution