Related Experiment Video
Updated: Jun 29, 2025

Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
Is the 5-Minute Time-Trial Cycling Test a Valid Predictor of Maximal Oxygen Uptake? An External Cross-Validation
Fernando Klitzke Borszcz1,2, Artur Ferreira Tramontin1, Ricardo Dantas de Lucas2
1Human Performance Research Group, Center for Health and Sport Sciences, Santa Catarina State University, Florianópolis, SC, Brazil.
Purpose:
This study aimed to cross-validate a recently proposed equation for the prediction of maximal oxygen uptake (V˙O2max) in cycling exercise by using the average power output normalized by the body mass from a 5-minute time trial (RPO5-min) as the independent variable. Further, the study aimed to update the predictive equation using Bayesian informative prior distributions and meta-analysis.
Methods:
On different days, 49 male cyclists performed an incremental graded exercise test until exhaustion and a 5-minute time trial on a stationary cycle ergometer. We compared the actual V˙O2max with the predicted value obtained from the RPO5-min, using a modified Bayesian Bland-Altman agreement analysis. In addition, this study updated the data on the linear regression between V˙O2max and RPO5-min, by incorporating information from a previous study as a Bayesian informative prior distribution or via meta-analysis.
Results:
On average, the predicted V˙O2max using RPO5-min underestimated the actual V˙O2max by -6.6 mL·kg-1·min-1 (95% credible interval, -8.6 to -4.7 mL·kg-1·min-1). The lower and upper 95% limits of agreement were -17.2 (-22.7 to -12.3) and 3.8 (-1.0 to 9.5) mL·kg-1·min-1, respectively. When the current study's data were analyzed using the previously published data as a Bayesian informative prior distribution, the accuracy of predicting sample means was found to be better when compared with the data combined via meta-analyses.
Conclusions:
The proposed equation presented systematic bias in our sample, in which the prediction underestimated the actual V˙O2max. We provide an updated equation using the previous one as the prior distribution, which could be generalized to a greater audience of cyclists.
More Related Videos
08:27A Real-World High-Intensity Interval Training Protocol for Cardiorespiratory Fitness Improvement
Published on: February 22, 2022
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Reliability and Validity
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...