Related Experiment Video
Updated: Jun 29, 2025

Behavioral Assessment of Manual Dexterity in Non-Human Primates
Published on: November 11, 2011
Deep Learning-Enhanced Hand Grip and Release Test for Degenerative Cervical Myelopathy: Shortening Assessment
Yongyu Ye1, Yunbing Chang1, Weihao Wu2,3
1Department of Orthopedic Surgery, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
Objective:
Hand clumsiness and reduced hand dexterity can signal early signs of degenerative cervical myelopathy (DCM). While the 10-second grip and release (10-s G&R) test is a common clinical tool for evaluating hand function, a more accessible method is warranted. This study explores the use of deep learning-enhanced hand grip and release test (DL-HGRT) for predicting DCM and evaluates its capability to reduce the duration of the 10-s G&R test.
Methods:
The retrospective study included 508 DCM patients and 1,194 control subjects. Propensity score matching (PSM) was utilized to minimize the confounding effects related to age and sex. Videos of the 10-s G&R test were captured using a smartphone application. The 3D-MobileNetV2 was utilized for analysis, generating a series of parameters. Additionally, receiver operating characteristic curves were employed to assess the performance of the 10-s G&R test in predicting DCM and to evaluate the effectiveness of a shortened testing duration.
Results:
Patients with DCM exhibited impairments in most 10-s G&R test parameters. Before PSM, the number of cycles achieved the best diagnostic performance (area under the curve [AUC], 0.85; sensitivity, 80.12%; specificity, 74.29% at 20 cycles), followed by average grip time. Following PSM for age and gender, the AUC remained above 0.80. The average grip time achieved the highest AUC of 0.83 after 6 seconds, plateauing with no significant improvement in extending the duration to 10 seconds, indicating that 6 seconds is an adequate timeframe to efficiently evaluate hand motor dysfunction in DCM based on DL-HGRT.
Conclusion:
DL-HGRT demonstrates potential as a promising supplementary tool for predicting DCM. Notably, a testing duration of 6 seconds appears to be sufficient for accurate assessment, enhancing the test more feasible and practical without compromising diagnostic performance.
More Related Videos
07:22Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
07:34Functional MRI in Conjunction with a Novel MRI-compatible Hand-induced Robotic Device to Evaluate Rehabilitation of Individuals Recovering from Hand Grip Deficits
Published on: November 23, 2019