Related Experiment Video
Updated: Jul 16, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective
Eic Ju Lim1, Jae-Woo Cho2, Oog-Jin Shon3
1Department of Orthopaedic Surgery, Chungbuk National University College of Medicine, Cheongju, Republic of Korea.
Background:
The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.
Methods:
This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.
Results:
There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg >10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.
Conclusions:
Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.
More Related Videos
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
04:42Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Bone Structure
Changes in the Appendicular Skeleton with Age
Initially, the limb buds consist of a core of mesenchyme covered by a layer of ectoderm. The ectoderm at the end of the limb bud thickens to form a narrow crest called the apical ectodermal ridge. This ridge stimulates the underlying...