Related Experiment Video
Updated: Jun 29, 2025

Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
Batch-to-batch reproducibility for the primary pH method for the example of NMIJ carbonate buffer solutions
Toshiaki Asakai1, Igor Maksimov2, Sachiko Onuma2
1National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan. t-asakai@aist.go.jp.
Abstract:
At present, the National Metrology Institute of Japan provides six national primary pH buffers under the Japan Calibration Service System. Each batch of these buffers is certified by the primary pH method using a Harned cell. On the basis of these primary buffers, the designated laboratories supply the secondary and working pH standards using a high-precision pH meter. This paper provides an estimate of the batch-to-batch reproducibility of the primary pH standard production based on the history of the certification of primary carbonate buffers in NMIJ. This buffer, which was chosen as the subject of the study because of the relative difficulty of its measurements (and thus a greater dispersion of results), is nominally the 0.025 mol kg-1 equimolal solution of disodium carbonate and sodium hydrogen carbonate. As its pH value is significantly affected by the purity of the reagents used, the evaluation of their source materials is made by both pH measurements and acidimetric gravimetric back titrations. Considering the experimentally determined pH reproducibility of ca. 0.010, potential risks to the pH accuracy are discussed when using recipe-based carbonate pH standards.
Related Concept Videos
Titration of Polyprotic Base with a Strong Acid
Calculating pH Changes in a Buffer Solution
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then: