Regulating and controlling the stepwise ESDPT channel of BP(OH)2DCEt2 using the strategy of solvent polarity and

Hongbin Zhuang1, Wei Shi1, Guijie Zhao1

  • 1School of Physics, Liaoning University, Shenyang 110036, P. R. China. yqli@lnu.edu.cn.

Related Concept Videos

Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
395
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
162
E2 Reaction: Kinetics and Mechanism02:45

E2 Reaction: Kinetics and Mechanism

SN2 substitutions and E2 eliminations of alkyl halides proceed via a concerted pathway. While the nucleophile attacks the alpha carbon in SN2 reactions, it functions as a strong base and abstracts a beta hydrogen in the E2 mechanism. The rate-limiting transition state in E2 elimination reactions is characterized by partially broken carbon–hydrogen and carbon–halogen bonds and a partially formed pi bond between the alpha and beta carbons. The beta hydrogen and halide are eliminated...
10.2K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
230
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
473
Leveling Effect01:29

Leveling Effect

In acid-base chemistry, the leveling effect refers to the limitation imposed by the solvent on the strength of acids and bases in solution. When a base stronger than the solvent's conjugate base is used, it deprotonates the solvent until the base is entirely consumed, making it ineffective against weaker acids. Conversely, an acid stronger than the solvent's conjugate acid protonates the solvent until the acid is depleted, rendering it ineffective against weaker bases. Essentially, the...
801