Related Experiment Video
Updated: Jun 29, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Comparison Static and Dynamic Ultrasound Techniques of DDH: The Role of the Patient's Position
Mohammad Reza Yousefi1, Mojgan Yazdanprast1, Hashem Neshati1
1Department of radiology, faculty medicine, Mashhad University of medical science, Iran.
Objectives:
The ultrasound examination of the hip joint is performed in the static (Graf) technique in the lateral recumbent position and in the dynamic technique in the supine position. This study compares the two static and dynamic techniques and assesses the role of the patient's position in the examination of DDH.
Methods:
This cross-sectional study was conducted in 2020-2021 at Akbar Hospital, Mashhad University of Medical Sciences, Iran. 126 patients suspected of having DDH (199 hip) infants were enrolled in the study. All ultrasound examinations were performed with two static and dynamic techniques by a pediatric radiologist.
Results:
In the static and dynamic ultrasound examinations, the average alpha angle was 51.57 ± 6.41 degrees, and 53.41 ± 6.94 degrees, respectively. These changes were not statistically significant (P = 0.312). The relationship and agreement between instability with dynamic technique and instability with static technique (IIC unstable, D, III, and IV) were investigated. Significant agreement (Kappa=0.77 (95% CI: 0.66-0.87) with excellent clinical significance was obtained between the two ultrasound examination method. Also, in terms of DDH types in the static method with instability types in the dynamic method, a substantial agreement was found between the two examination methods (Kappa =0.67; (95% CI: 0.59-0.75) with good clinical significance.
Conclusion:
In the ultrasound examination of DDH with static and dynamic techniques, the change in the alpha angle was not statistically significant. Therefore, the hand of the radiologist is open in measuring alpha angles and there is no need to emphasize a specific position. The type of DDH in the static technique completely corresponded to the type of stability or instability in the dynamic technique.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

