Related Experiment Video
Updated: Jun 29, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Preclinical evaluation of Tc-99m p5+14 peptide for SPECT detection of cardiac amyloidosis
Stephen J Kennel1, Joseph W Jackson1, Alan Stuckey1
1Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, United States of America.
Introduction:
Amyloid deposition is a cause of restrictive cardiomyopathy. Patients who present with cardiac disease can be evaluated for transthyretin (TTR)-associated cardiac amyloidosis using nuclear imaging with 99mTc-labeled pyrophosphate (PYP); however, light chain-associated (AL) cardiac amyloid is generally not detected using this tracer. As an alternative, the amyloid-binding peptide p5+14 radiolabeled with iodine-124 has been shown to be an effective pan-amyloid radiotracer for PET/CT imaging. Here, a 99mTc-labeled form of p5+14 peptide has been prepared to facilitate SPECT/CT imaging of cardiac amyloidosis.
Method:
A synthesis method suitable for clinical applications has been used to prepare 99mTc-labeled p5+14 and tested for peptide purity, product bioactivity, radiochemical purity and stability. The product was compared with99mTc-PYP for cardiac SPECT/CT imaging in a mouse model of AA amyloidosis and for reactivity with human tissue sections from AL and TTR patients.
Results:
The 99mTc p5+14 tracer was produced with >95% yields in radiopurity and bioactivity with no purification steps required and retained over 95% peptide purity and >90% bioactivity for >3 h. In mice, the tracer detected hepatosplenic AA amyloid as well as heart deposits with uptake ~5 fold higher than 99mTc-PYP. 99mTc p5+14 effectively bound human amyloid deposits in the liver, kidney and both AL- and ATTR cardiac amyloid in tissue sections in which 99mTc-PYP binding was not detectable.
Conclusion:
99mTc-p5+14 was prepared in minutes in >20 mCi doses with good performance in preclinical studies making it suitable for clinical SPECT/CT imaging of cardiac amyloidosis.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

