Measurement of Spatial Stability in Precision Grip
Published on: June 4, 2020
Testing protocols and measurement techniques when using pressure sensors for sport and health applications: A
Louise Burnie1, Nachiappan Chockalingam2, Alex Holder3
1Department of Sport, Exercise and Rehabilitation, Faculty of Health & Life Sciences, Northumbria University, Newcastle upon Tyne NE1 8ST, UK; Applied Sports, Technology, Exercise and Medicine (A-STEM) Research Centre, Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK.
Abstract:
Plantar pressure measurement systems are routinely used in sports and health applications to assess locomotion. The purpose of this review is to describe and critically discuss: (a) applications of the pressure measurement systems in sport and healthcare, (b) testing protocols and considerations for clinical gait analysis, (c) clinical recommendations for interpreting plantar pressure data, (d) calibration procedures and their accuracy, and (e) the future of pressure sensor data analysis. Rigid pressure platforms are typically used to measure plantar pressures for the assessment of foot function during standing and walking, particularly when barefoot, and are the most accurate for measuring plantar pressures. For reliable data, two step protocol prior to contacting the pressure plate is recommended. In-shoe systems are most suitable for measuring plantar pressures in the field during daily living or dynamic sporting movements as they are often wireless and can measure multiple steps. They are the most suitable equipment to assess the effects of footwear and orthotics on plantar pressures. However, they typically have lower spatial resolution and sampling frequency than platform systems. Users of pressure measurement systems need to consider the suitability of the calibration procedures for their chosen application when selecting and using a pressure measurement system. For some applications, a bespoke calibration procedure is required to improve validity and reliability of the pressure measurement system. The testing machines that are commonly used for dynamic calibration of pressure measurement systems frequently have loading rates of less than even those found in walking, so the development of testing protocols that truly measure the loading rates found in many sporting movements are required. There is clear potential for AI techniques to assist in the analysis and interpretation of plantar pressure data to enable the more complete use of pressure system data in clinical diagnoses and monitoring.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)