Related Experiment Video
Updated: Jun 29, 2025

The Visual Colorimetric Detection of Multi-nucleotide Polymorphisms on a Pneumatic Droplet Manipulation Platform
Published on: September 27, 2016
Further research into alternative carrier solvents for the detection of latent fingermarks
Joel Able1, Rachel Armitage2, Paul Deacon3
1Faculty of Health and Life Sciences, Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK.
Abstract:
A number of solvents, (Solstice PF, Opteon SF33 and Amolea AS-300), are compared to the recommended carrier solvent of HFE7100 for the ninhydrin and 1,2-indandione formulations. As the supply of HFE7100 will cease by the end of 2025, suitable alternatives are required in the short-term to ensure the detection of latent fingermarks on porous surfaces is still effective. Although these solvents, with the exception of Amolea AS-300, are classified as per- and polyfluoroalkyl substances (PFAS); they are not classed as hazardous. The alternatives in this study have a low global warming potential and atmospheric lifetime and are volatile, non-flammable and non-ozone depleting, in addition to other desirable properties such as a high wetting-index. During Phase 2 trials with deposited fingermarks, HFE7100 provided the best performing results followed by Opteon SF33, Solstice PF and Amolea AS-300. A significant difference with a negligible effect size was observed for ninhydrin formulations (p-value 0.00179; ε2 0.00418) while a significant difference with a weak effect size was observed for 1,2-indanedione formulations (p-value 2.095 ×10-10; ε2 0.0167). Furthermore, HFE7100 provided the least ink diffusion and the brightest 1,2-indanedione luminosity (significant difference with a moderate effect size p-value 1.772 ×10-13; ε2 0.0434) but the HFE formulation turned cloudy more quickly and needed regular replacements. Phase 3 pseudo-operational trials of 100 porous items followed a similar trend whereby HFE7100 formulations detected the highest number of marks followed by Opteon SF33 and Solstice PF. Although HFE7100 is still the best performing carrier solvent, this study demonstrates that, in the short-term, Opteon SF33 and Solstice PF may have potential as non-flammable replacement carrier solvents while developing the long-term goal of solvent-less methods.
More Related Videos
07:10Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out
Published on: November 9, 2018
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors