Related Experiment Video
Updated: Jul 18, 2026

Introducing an Angle Adjustable Cutting Box for Analyzing Slice Shear Force in Meat
Published on: April 26, 2013
Objective grading of rib eye traits using the Q-FOM™ camera in Australian beef carcasses
Sarah M Stewart1, Henrik Toft2, Rachel A O'Reilly1
1Advanced Livestock Measurement Technologies (ALMTech) Project, School of Agriculture, Murdoch University, Western Australia 6150, Australia.
Abstract:
The objective of this study was to develop calibration models against rib eye traits and independently validate the precision, accuracy, and repeatability of the Frontmatec Q-FOM™ Beef grading camera in Australian carcasses. This study compiled 12 different research datasets acquired from commercial processing facilities and were comprised of a diverse range of carcass phenotypes, graded by industry identified expert Meat Standards Australia (MSA) graders and sampled for chemical intramuscular fat (IMF%). Calibration performance was maintained when the device was independently validated. For continuous traits, the Q-FOM™ demonstrated precise (root mean squared error of prediction, RMSEP) and accurate (coefficient of determination, R2) prediction of eye muscle area (EMA) (R2 = 0.89, RMSEP = 4.3 cm2, slope = 0.96, bias = 0.7), MSA marbling (R2 = 0.95, RMSEP = 47.2, slope = 0.98, bias = -12.8) and chemical IMF% (R2 = 0.94, RMSEP = 1.56%, slope = 0.96, bias = 0.64). For categorical traits, the Q-FOM™ predicted 61%, 64.3% and 60.8% of AUS-MEAT marbling, meat colour and fat colour scores equivalent, and 95% within ±1 classes of expert grader scores. The Q-FOM™ also demonstrated very high repeatability and reproducibility across all traits.
More Related Videos
08:52Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
07:46Author Spotlight: Improving Beef Cattle Nutrition and Production with a Focus on Feed Efficiency and Meat Quality Traits Through Advanced Biochemical and Molecular Assays
Published on: July 12, 2024
Related Concept Videos
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Bone Markings
Articulating Projections
Articulating projections are found where two bones meet to form a joint. These structures are usually found at the ends of bones. The largest articulation is a rounded projection called the head, supported by a narrow neck at the ends of...
Assessment of the Abdomen III: Palpation
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography