Ultrasound Viscosity Imaging in Breast Lesions: A Multicenter Prospective Study
WanRu Jia1, ShuJun Xia1, XiaoHong Jia2
1Department of Ultrasound, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No.197 Ruijin 2nd Road, 200025 Shanghai, China; College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
Rationale And Objectives:
To explore and validate the clinical value of ultrasound (US) viscosity imaging in differentiating breast lesions by combining with BI-RADS, and then comparing the diagnostic performances with BI-RADS alone.
Materials And Methods:
This multicenter, prospective study enrolled participants with breast lesions from June 2021 to November 2022. A development cohort (DC) and validation cohort (VC) were established. Using histological results as reference standard, the viscosity-related parameter with the highest area under the receiver operating curve (AUC) was selected as the optimal one. Then the original BI-RADS would upgrade or not based on the value of this parameter. Finally, the results were validated in the VC and total cohorts. In the DC, VC and total cohorts, all breast lesions were divided into the large lesion, small lesion and overall groups respectively.
Results:
A total of 639 participants (mean age, 46 years ± 14) with 639 breast lesions (372 benign and 267 malignant lesions) were finally enrolled in this study including 392 participants in the DC and 247 in the VC. In the DC, the optimal viscosity-related parameter in differentiating breast lesions was calculated to be A'-S2-Vmax, with the AUC of 0.88 (95% CI: 0.84, 0.91). Using > 9.97 Pa.s as the cutoff value, the BI-RADS was then modified. The AUC of modified BI-RADS significantly increased from 0.85 (95% CI: 0.81, 0.88) to 0.91 (95% CI: 0.87, 0.93), 0.85 (95% CI: 0.80, 0.89) to 0.90 (95% CI: 0.85, 0.93) and 0.85 (95% CI: 0.82, 0.87) to 0.90 (95% CI: 0.88, 0.92) in the DC, VC and total cohorts respectively (P < .05 for all).
Conclusion:
The quantitative viscous parameters evaluated by US viscosity imaging contribute to breast cancer diagnosis when combined with BI-RADS.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
10:21A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...