Summary
Transcatheter aortic valve replacement (TAVR) can cause cardiac conduction abnormalities (CCA). Deeper implantation and right bundle branch block increase CCA risk, while aortic deployment and left bundle branch block may reduce it.
Area of Science:
- Cardiovascular Medicine
- Biomedical Engineering
- Computational Biology
Background:
- Transcatheter aortic valve replacement (TAVR) is increasingly preferred over surgical aortic valve replacement (SAVR).
- Cardiac conduction abnormalities (CCA) remain a significant complication following TAVR.
- Pressure from the TAVR stent on cardiac conduction fibers near the AV node can cause CCA.
Conclusions:
- Implantation depth and pre-existing conduction abnormalities critically influence post-TAVR CCA risk.
- Aortic deployment and LBBB may mitigate CCA risk, whereas deeper placement and RBBB elevate it.