Related Experiment Video
Updated: Jun 29, 2025

Modifying the Bank Erosion Hazard Index BEHI Protocol for Rapid Assessment of Streambank Erosion in Northeastern Ohio
Published on: February 13, 2015
Couple-Years of Protection Indicator: New Global Guidance for Updating Existing Methods and Adding New Methods
Elena Lebetkin1, Markus J Steiner2, Emily Sonneveldt3
1FHI 360, Durham, NC, USA. elebetkin@fhi360.org.
Background:
Couple-years of protection (CYP) is an indicator that allows for monitoring and evaluating of family planning (FP) program performance through simple calculations. The CYP for each contraceptive method is calculated by multiplying the number of contraceptive commodity units distributed to clients over a 1-year period by a conversion factor that quantifies the duration of contraceptive protection provided per unit distributed. CYP calculations across methods were previously updated in 2000 and 2011, resulting in changes in methodology, factor inclusion, and specific methods. Since the 2011 update, changes and additions to the modern contraceptive method mix required new CYP conversion factors for 4 methods of contraception: Levoplant implant, progestin-only pills (POPs), Caya diaphragm, and the hormonal intrauterine device.
Methods:
We conducted literature reviews of both published and gray literature and consulted with experts to identify updated data on continuation rates, duration of efficacy, and method effectiveness for the 4 methods. New CYP conversion factors were calculated for the 4 methods either by using the same calculation used previously for the method considering new data or, for new methods, using calculations for similar methods.
Results:
New CYP conversion factors were assigned to the 4 methods of contraception covered in this update: Levoplant, 2.5 CYP per implant inserted; POPs, 0.0833 CYP per pack (i.e., 12 cycles per CYP); Caya diaphragm, 1 CYP per device, and hormonal intrauterine device, 4.8 CYP per device inserted.
Conclusions:
CYP is an important indicator for FP programs. As new methods of contraception are developed and new evidence is generated for current methods, the indicator may need to be updated. A standard process for updating and documenting future CYP updates is recommended.
More Related Videos
11:13Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
08:23Real-Time Impedance-based Cell Analyzer as a Tool to Delineate Molecular Pathways Involved in Neurotoxicity and Neuroprotection in a Neuronal Cell Line
Published on: August 9, 2014
Related Concept Videos
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Legal Guidelines for Documentation
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Corrosion
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...