Related Experiment Video
Updated: Jun 29, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Mechanical characteristics analysis of high dimensional vibration isolation systems based on high-static-low-dynamic
Bu-Yun Li1,2, Chang-Geng Shuai1,2, Jian-Guo Ma3,4
1Institute of Noise & Vibration, Naval University of Engineering, Wuhan, 430030, People's Republic of China.
Abstract:
Large floating raft vibration isolation systems (FRVISs) based on high-static-low-dynamic stiffness (HSLDS) technology offer excellent low frequency vibration isolation performance with broad application prospects. However, the design process for these complex high-dimensional coupled nonlinear systems remains poorly developed, particularly when applied for ocean-going vessels that experience rolling and pitching motions. The present work addresses this issue by establishing a six-degree-of-freedom HSLDS vibration isolation model for FRVISs composed of eight isolators, and the model is applied to fully analyze the swing stability and multidimensional vibration isolation performance of these systems. The influence of nonlinearity on the mechanical properties of the vibration isolators is analyzed more clearly by assuming that each vibration isolator realizes nonlinear HSLDS characteristics in the z direction and linear characteristics in the x and y directions. The results demonstrate that the swing displacement responses of the system are greatly reduced under weak nonlinearity, which reflects the high static stiffness and high static stability characteristics of an HSLDS system. The multidimensional vibration isolation performance of the system is evaluated according to the impacts of nonlinearity, the installation height Hz of the isolators, and the relative position Dr of the two middle isolators. The results of analysis demonstrate that applying a value of Hz = 0 produces the best vibration isolation performance overall under strong nonlinearity by avoiding unnecessary secondary peaks in the force transmission rate under harmonic mechanical excitation and ensuring a maximum high-frequency vibration isolation effect. However, applying a weak nonlinearity is better than a strong nonlinearity if Hz is not zero. In contrast, Dr has little effect on the vibration isolation effect of the raft in the x, y, and z directions. Therefore, an equidistant installation with Dr = 0.5 would be considered ideal from the standpoint of installation stability.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
08:27Author Spotlight: Efficient Image Recognition Using Directional Gradient Histogram Technique and Support Vector Machines
Published on: January 5, 2024
Related Concept Videos
Mechanical Systems
Stability of structures
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Thin-Walled Hollow Shafts
Statically Indeterminate Problem Solving
Residual Stresses in Circular Shafts