Related Experiment Video
Updated: Jun 29, 2025

Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Application of a hydrophobic coating to a pressurized pipe and its effect on energy losses and fluid flow profile
Antonio J Muñóz1, Juan Reca2,3, Juan Martínez1,4
1Department of Engineering, University of Almería, Ctra. Sacramento S.N. La Cañada de S. Urbano, 04129, Almería, Spain.
Abstract:
The use of additives, generally called DRAs (Drag Reducing Additives), has been proposed to re-duce the energy consumption in pressurized pipes. Although many research works have been conducted to analyze the effect of these additives, less attention have been devoted to the application of coatings to the pipe wall. This paper demonstrates that the application of a hydrophobic coating to the pipe can lead to a head loss reduction for a transition flow regime with moderate Reynolds number values (Re). For this purpose, an experiment was conducted to compare the performance of both coated and uncoated pipes by measuring the head losses and assessing the Drag Reduction Percentage (%DR) and the pipe friction factor (f). This was done for two Polyvinylchloride (PVC) pipes with different nominal diameters (PVC90 and PVC63). In addition, the flow velocity distribution was also measured in all these tests. The %DR decreased as the Re values increased, with the reduction being notably less pronounced for higher Re values. This could be explained by the fact that a partial slip condition is induced by the hydrophobic product. Its effect is significant for a transition regime where the effect of viscosity is important, but it becomes negligible for increasing levels of turbulence. No significant differences were observed in the flow distribution between coated and uncoated pipes, which seems to indicate that the velocity change could be limited to the near-wall viscous sublayer. The results of this work open an important research line aimed at reducing energy costs and the carbon footprint in pipe fluid distribution systems.
Related Concept Videos
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
Design Example: Flow of Oil Through Circular Pipes
General Characteristics of Pipe Flow II
The distance to reach a fully developed flow is called the entrance length and depends on the...
Laminar Flow
Fluid Pressure over Flat Plate of Constant Width
The resultant force...