Related Experiment Video
Updated: Jun 29, 2025

Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
Prediction model for anabolic androgenic steroid positivity in forensic autopsy cases - a new tool to the autopsy
Paula Vauhkonen1,2, Petteri Oura3,4, Pirkko Kriikku4,5
1Forensic Medicine Unit, Finnish Institute for Health and Welfare, Mannerheimintie 166, P.O. Box 30, FI-00271, Helsinki, Finland. paula.vauhkonen@helsinki.fi.
Abstract:
Non-prescription use of anabolic androgenic steroids (AAS) is associated with an increased risk of premature death. However, these substances are seldom screened in connection with forensic cause-of-death investigation, unless the forensic pathologist specifically suspects use, often based on a positive AAS use history. Since AAS use is often concealed from others, this practice may lead to mistargeting of these analyses and significant underestimation of the true number of AAS positive cases undergoing forensic autopsy. Thus, more accurate diagnostic tools are needed to identify these cases. The main objective of this study was to determine, whether a multivariable model could predict AAS urine assay positivity in forensic autopsies. We analyzed retrospectively the autopsy reports of all cases that had been screened for AAS during forensic cause-of-death investigation between 2016-2019 at the Finnish Institute for Health and Welfare forensic units (n = 46). Binary logistic regression with penalized maximum likelihood estimation was used to generate a nine-variable model combining circumferential and macroscopic autopsy-derived variables. The multivariable model predicted AAS assay positivity significantly better than a "conventional" model with anamnestic information about AAS use only (area under the receiver operating characteristic curve [AUC] = 0.968 vs. 0.802, p = 0.005). Temporal validation was conducted in an independent sample of AAS screened cases between 2020-2022 (n = 31), where the superiority of the multivariable model was replicated (AUC = 0.856 vs. 0.644, p = 0.004). Based on the model, a calculator predicting AAS assay positivity is released as a decision-aiding tool for forensic pathologists working in the autopsy room.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:49Enhanced Genetic Analysis of Single Human Bioparticles Recovered by Simplified Micromanipulation from Forensic ‘Touch DNA’ Evidence
Published on: March 9, 2015