Related Experiment Video
Updated: Jun 29, 2025

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Test-retest reliability of transfer function analysis metrics for assessing dynamic cerebral autoregulation to
Markus Harboe Olsen1, Christian Riberholt1,2, Tenna Capion3
1Department of Neuroanaesthesiology, The Neuroscience Centre, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
Abstract:
Transfer function analysis (TFA) is a widely used method for assessing dynamic cerebral autoregulation in humans. In the present study, we assessed the test-retest reliability of established TFA metrics derived from spontaneous blood pressure oscillations and based on 5 min recordings. The TFA-based gain, phase and coherence in the low-frequency range (0.07-0.20 Hz) from 19 healthy volunteers, 37 patients with subarachnoid haemorrhage and 19 patients with sepsis were included. Reliability assessments included the smallest real difference (SRD) and the coefficient of variance for comparing consecutive 5 min recordings, temporally separated 5 min recordings and consecutive recordings with a minimal length of 10 min. In healthy volunteers, temporally separating the 5 min recordings led to a 0.38 (0.01-0.79) cm s-1 mmHg-1 higher SRD for gain (P = 0.032), and extending the duration of recordings did not affect the reliability. In subarachnoid haemorrhage, temporal separation led to a 0.85 (-0.13 to 1.93) cm s-1 mmHg-1 higher SRD (P = 0.047) and a 20 (-2 to 41)% higher coefficient of variance (P = 0.038) for gain, but neither metric was affected by extending the recording duration. In sepsis, temporal separation increased the SRD for phase by 94 (23-160)° (P = 0.006) but was unaffected by extending the recording. A recording duration of 8 min was required to achieve stable gain and normalized gain measures in healthy individuals, and even longer recordings were required in patients. In conclusion, a recording duration of 5 min appears insufficient for obtaining stable and reliable TFA metrics when based on spontaneous blood pressure oscillations, particularly in critically ill patients with subarachnoid haemorrhage and sepsis.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....

