Related Experiment Video
Updated: Jun 29, 2025

Segmentation and Linear Measurement for Body Composition Analysis using Slice-O-Matic and Horos
Published on: March 21, 2021
Influence of Body Mass Index on Radiation Exposure Across Imaging Modalities in the Evaluation of Chest Pain
Brett W Sperry1,2, Mary Stefanie Vamenta1,2, Satya Preetham Gunta2
1Saint Luke's Mid America Heart Institute Kansas City MO.
Background:
Essential to a patient-centered approach to imaging individuals with chest pain is knowledge of differences in radiation effective dose across imaging modalities. Body mass index (BMI) is an important and underappreciated predictor of effective dose. This study evaluated the impact of BMI on estimated radiation exposure across imaging modalities.
Methods And Results:
This was a retrospective analysis of patients with concern for cardiac ischemia undergoing positron emission tomography (PET)/computed tomography (CT), cadmium zinc telluride single-photon emission CT (SPECT) myocardial perfusion imaging, or coronary CT angiography (CCTA) using state-of-the-art imaging modalities and optimal radiation-sparing protocols. Radiation exposure was calculated across BMI categories based on established cardiac imaging-specific conversion factors. Among 9046 patients (mean±SD age, 64.3±13.1 years; 55% men; mean±SD BMI, 30.6±6.9 kg/m2), 4787 were imaged with PET/CT, 3092 were imaged with SPECT/CT, and 1167 were imaged with CCTA. Median (interquartile range) radiation effective doses were 4.4 (3.9-4.9) mSv for PET/CT, 4.9 (4.0-6.3) mSv for SPECT/CT, and 6.9 (4.0-11.2) mSv for CCTA. Patients at a BMI <20 kg/m2 had similar radiation effective dose with all 3 imaging modalities, whereas those with BMI ≥20 kg/m2 had the lowest effective dose with PET/CT. Radiation effective dose and variability increased dramatically with CCTA as BMI increased, and was 10 times higher in patients with BMI >45 kg/m2 compared with <20 kg/m2 (median, 26.9 versus 2.6 mSv). After multivariable adjustment, PET/CT offered the lowest effective dose, followed by SPECT/CT, and then CCTA (P<0.001).
Conclusions:
Although median radiation exposure is modest across state-of-the-art PET/CT, SPECT/CT, and CCTA systems using optimal radiation-sparing protocols, there are significant variations across modalities based on BMI. These data are important for making patient-centered decisions for ischemic testing.
More Related Videos
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
06:48Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation