Related Experiment Video
Updated: Jun 29, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Pilot study to evaluate left-to-right ventricular offset in biventricular pacing-comparison of electrocardiographic
Amit Noheria1, Ahmed Shahab1, Christopher Andrews2
1Department of Cardiovascular Medicine, The University of Kansas Medical Center, Kansas City, Kansas, USA.
Introduction:
Biventricular pacing (BiVp) improves outcomes in systolic heart failure patients with electrical dyssynchrony. BiVp is delivered from epicardial left ventricular (LV) and endocardial right ventricular (RV) electrodes. Acute electrical activation changes with different LV-RV stimulation offsets can help guide individually optimized BiVp programming. We sought to study the BiVp ventricular activation with different LV-RV offsets and compare with 12-lead ECG.
Methods:
In five patients with BiVp (63 ± 17-year-old, 80% male, LV ejection fraction 27 ± 6%), we evaluated acute ventricular epicardial activation, varying LV-RV offsets in 20 ms increments from -40 to 80 ms, using electrocardiographic imaging (ECGI) to obtain absolute ventricular electrical uncoupling (VEUabs, absolute difference in average LV and average RV activation time) and total activation time (TAT). For each patient, we calculated the correlation between ECGI and corresponding ECG (3D-QRS-area and QRS duration) with different LV-RV offsets.
Results:
The LV-RV offset to attain minimum VEUabs in individual patients ranged 20-60 ms. In all patients, a larger LV-RV offset was required to achieve minimum VEUabs (36 ± 17 ms) or 3D-QRS-area (40 ± 14 ms) than that for minimum TAT (-4 ± 9 ms) or QRS duration (-8 ± 11 ms). In individual patients, 3D-QRS-area correlated with VEUabs (r 0.65 ± 0.24) and QRS duration correlated with TAT (r 0.95 ± 0.02). Minimum VEUabs and minimum 3D-QRS-area were obtained by LV-RV offset within 20 ms of each other in all five patients.
Conclusions:
LV-RV electrical uncoupling, as assessed by ECGI, can be minimized by optimizing LV-RV stimulation offset. 3D-QRS-area is a surrogate to identify LV-RV offset that minimizes LV-RV uncoupling.
More Related Videos
09:52Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...