Deep learning assists in acute leukemia detection and cell classification via flow cytometry using the acute leukemia
Fu-Ming Cheng1, Shih-Chang Lo2, Ching-Chan Lin1
1Division of Hematology and Oncology, Department of Internal Medicine, China Medical University Hospital, China Medical University, Taichung, 404, Taiwan.
Abstract:
This study aimed to evaluate the sensitivity of AI in screening acute leukemia and its capability to classify either physiological or pathological cells. Utilizing an acute leukemia orientation tube (ALOT), one of the protocols of Euroflow, flow cytometry efficiently identifies various forms of acute leukemia. However, the analysis of flow cytometry can be time-consuming work. This retrospective study included 241 patients who underwent flow cytometry examination using ALOT between 2017 and 2022. The collected flow cytometry data were used to train an artificial intelligence using deep learning. The trained AI demonstrated a 94.6% sensitivity in detecting acute myeloid leukemia (AML) patients and a 98.2% sensitivity for B-lymphoblastic leukemia (B-ALL) patients. The sensitivities of physiological cells were at least 80%, with variable performance for pathological cells. In conclusion, the AI, trained with ResNet-50 and EverFlow, shows promising results in identifying patients with AML and B-ALL, as well as classifying physiological cells.
More Related Videos
09:01Flow Cytometry to Estimate Leukemia Stem Cells in Primary Acute Myeloid Leukemia and in Patient-derived-xenografts, at Diagnosis and Follow Up
Published on: March 26, 2018
12:05Database-guided Flow-cytometry for Evaluation of Bone Marrow Myeloid Cell Maturation
Published on: November 3, 2018