Evaluation of skull bone viability and effect of early surgical intervention in electrical contact burns using 18
Parmod Kumar1, Pulkit Arora1, Rajender Kumar2
1Departments of Plastic Surgery.
Objective:
Electrical contact burns of the scalp cause serious morbidity and mortality. Early necrotic bone debridement and flap cover are crucial for successful wound closure. 18 F Sodium Fluoride (NaF), with high bone-to-soft tissue activity ratio, is useful for bone viability assessment. This study evaluated the role of 18 F NaF PET-computed tomography (CT) in objectively defining the extent and depth of nonviable calvarial bone, to guide adequate bone debridement.
Method:
Of 20 patients referred to our institute with electrical contact burns of the scalp during a 2-year period, 15 were enrolled in the study. Two weeks after the initial management, tracer uptake pattern was noted on 18 F NaF PET-CT of the head and exposed bone measured. Surgical bone debridement was based on scan findings, followed by wound closure. All patients underwent clinical evaluation and follow-up scan 3 months after surgery.
Results:
Eight patients showed a central photopenic area in the exposed bone (maximum standardized uptake value [SUVmax] of 0.76 ± 0.14 with mean maximum dimensions 4.10 ± 1.76/2.67 ± 1.54 cm). High tracer uptake (SUVmax, 9.66 ± 6.03) was seen peripheral to the exposed bone (mean maximum dimensions, 8.14 ± 3.03/4.75 ± 1.61 cm). Postoperatively, there was no significant change in tracer uptake in the central debrided region or peri-debridement bone area under the flap. Clinically all patients showed a well-healed flap.
Conclusion:
18 F NaF PET-CT appears useful for objective evaluation of skull bone viability and planning necrotic bone debridement in patients with electrical contact burns. However, additional studies with longer patient follow-up are required to validate these results.