Related Experiment Video
Updated: Jun 28, 2025

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Is Using a Ring External Fixator in the Treatment of Congenital Pseudarthrosis of the Tibia Associated With Better
Ramin Zargarbashi1, Ali Bagherpour2, Behnam Panjavi1
1Children's Medical Center, Tehran University of Medical Sciences, Tehran.
Background:
Congenital pseudarthrosis of the tibia (CPT) is a rare disease. CPT is often unilateral and occurs between the middle and distal third of the tibia. Concurrent involvement of the fibula is present in more than half of cases. histologic studies indicate the presence of fibrous hamartoma tissue and a sick periosteum, which leads to recalcitrant bone fracture and, eventually, pseudoarthrosis. Although there are various surgical techniques, we intend to compare the 2 methods of external fixation versus internal plating.
Methods:
Demographic data were collected from 26 patients with frank pseudoarthrosis. After exclusion criteria, patients were compared in groups A (12 patients) and B (11 patients). Resection of hamartoma and sclerotic bone, intramedullary rodding and autologous bone, and periosteal grafting were performed for all patients. In group A, we used a ring external fixator for compression and rotational stability, but in group B, a locking plate was used for these purposes.
Results:
Plating takes less time to use during surgery. In group A, the primary bony union was obtained in 67% of patients, while in group B, 82% of patients had a primary union. Meanwhile, the average time till the final union in group A was 6 months, while in group B, this time was 3.5 months. Positive union mass was obtained in 58% of the patients in group A and 82% of group B. In addition, plating prevented ankle valgus deformity in group B.
Conclusions:
Permanent intramedullary rodding is a surgical requirement for correction of deformity and refracture prevention, but additional stability can be achieved with the use of a ring external fixator or internal plate. Cross union and positive union mass are 2 important factors in the treatment of pseudoarthrosis; these results are achieved to a greater extent and in a shorter period of time using the plate.
Level Of Evidence:
level IV - case series.
More Related Videos
04:42Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015