Related Experiment Video
Updated: Jun 28, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Microscopic Evaluation of Dentinal Defects after Root Canal Preparation with Different Hand and Nickel-Titanium
Hiral Milap Karia1, Ishita Vaghela2, Archan Dhanesha3
1Department of Conservative and Endodontics, R.R. Dental College, Udaipur, Rajasthan, India.
Background:
Effective endodontic instrumentation aims to remove microorganisms, debris, and tissue from the root canal while maintaining dentinal integrity. This study compares dentinal defect incidence following canal preparation with different hand files, nickel-titanium rotary files, and reciprocating files.
Materials And Methods:
Eighty single-rooted mandibular premolars with mature apices were collected. Four groups (n = 20) were established based on canal patency establishment, canal preparation technique, irrigation solution, and final irrigation. After root sectioning at 3 mm, 6 mm, and 9 mm from the apex, slices were examined under a stereomicroscope, and dentinal defects were recorded. A second examiner reviewed the images.
Results:
The results showed significant difference of P = 0.031 among Hand files vs. Rotary ProTaper files: In Hand files vs. Reciprocating WaveOne files significant difference was P = 0.048, and for rotary ProTaper files vs. Reciprocating WaveOne files: No significant difference (P = 0.643). Dentinal defect counts were similar at 3 mm, 6 mm, and 9 mm. Statistically significant variation was observed between hand files and rotary files, as well as hand files and reciprocating files.
Conclusion:
Both rotary and reciprocating files showed a statistically significant increase in dentinal defect incidence compared to hand files. However, clinical implications should be considered cautiously. Instrumentation technique selection should be based on clinical context, operator experience, and patient factors. Further clinical studies are needed for validation.
More Related Videos
06:16Author Spotlight: Establishing an Accurate Microhardness Testing Protocol for Craniofacial Tissues
Published on: April 26, 2024
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material