Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of the thicknesses of bulk-fill composites on bonding strength
Ying Wang1, Jiaxue Yang2, Haifeng Xie2
1Dept. of Endodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatology, Nanjing 210029, China.
Objectives:
This work evaluated the effects of thickness on resin bonding strength.
Methods:
We set the two bulk-fill composites Filtek Bulk Fill Posterior (FBF) and Tetric N-Ceram Bulk Fill (TBF) as the experimental groups and the two conventional composites Filtek Z100 (Z100) and Spectrum TPH (ST) as the control groups. The translucency parameter (TP), color difference, Vickers hardness (HV), and microtensile bond strength (μTBS) of dentine and the resin composites were measured at different depths.
Results:
In each group, TP and HV decreased with the increase in thickness. At the same depth, the TP of the bulk-fill composites was higher than that of the conventional composites. At the same depth, the HV of the four different resin composites followed the order of Z100>FBF>TBF>ST (except for the upper surface). Except for FBF at 3 and 4 mm, all of the other groups showed no visible color change at all the tested thicknesses. Although the μTBS values of the four different composites obtained through the bulk-fill technique were lower than those of composites obtained through the incremental fill technique, the μTBS of the bulk-fill composites obtained through the bulk-filling technique can reach 30 MPa.
Conclusions:
Bulk-fill composites applied in single 4 mm increments can meet the requirements of clinical application. However, the color stability of some bulk-fill composites cannot be maintained.
Related Concept Videos
Bonding and Strength of Aggregate
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Bulk Density of Aggregate
Most natural mineral aggregates, like sand and gravel,...
Relation Between Tensile Strength and Compressive Strength of Concrete
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...