Applicability of self-consistent reaction field (SCRF) method to DFT estimation of hydrogen isotope separation
Satoshi Yanase1, Yoshikazu Kikawada1, Takao Oi1
1Department of Materials and Life Sciences, Faculty of Science and Technology, Sophia University, Tokyo, Japan.
Abstract:
In earlier quantum chemical calculations of isotope effects, chemical species in the liquid phase were generally treated as existing in the gas phase. In recent years, however, advances in computational programs have made it easier for the self-consistent reaction field (SCRF) method to handle chemical species in the liquid phase, and as a result, it has become easier to apply the SCRF method to isotope effect calculations. This paper concerns the scope of application of the DFT-SCRF method to reversible processes for hydrogen isotope enrichment. It is found that the applicability of the method depends on the type of the intermolecular interaction in the liquid phase and the degree of hydrogen isotope effect (separation factor) on which the process is based. When the magnitude of the isotope effect of the separation system is greater than 10-1, the simple SCRF method is fully applicable; when the magnitude is around 10-2, SCRF with a dimer model, in which the monomer is replaced by a dimer, is applicable for the analysis of the liquid phase with relatively strong intermolecular interactions. Anharmonic correction to the separation factor calculated based on harmonic frequencies may be effective to systems with the liquid phase with weak intermolecular interactions.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
10:52Line Shape Analysis of Dynamic NMR Spectra for Characterizing Coordination Sphere Rearrangements at a Chiral Rhenium Polyhydride Complex
Published on: July 27, 2022
Related Concept Videos
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
High-Resolution Mass Spectrometry (HRMS)
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...