Related Experiment Video
Updated: Jun 28, 2025

Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Skin conductance algesimeter is unreliable during sudden perioperative temperature increases
Ulf E Kongsgaard1,2, Robin Johansen Menchini1, Stein Gunnar Larsen3
1Department of Anaesthesia, The Norwegian Radium Hospital, Oslo University Hospital, Oslo, Norway.
Objectives:
Pain assessment in anesthetized and non-communicative patients remains a challenge. Clinical signs such as tachycardia, hypertension, sweat and tears, have a low specificity for pain and should therefore ideally be replaced by more specific monitoring techniques. Skin conductance variability has been demonstrated to establish a patients' sensitivity to pain, but may be influenced by temperature changes that leads to profuse sweating. The aim of this pilot study was to test skin conductance changes during sudden temperature changes due to hyperthermic intraperitoneal chemotherapy (HIPEC) perfusation.
Methods:
We investigated skin conductance algesimeter (SCA) in ten consecutive patients undergoing cytoreductive surgery and HIPEC. Results from the SCA was compared to other standard physiological variables at seven time points during the surgical procedure, in particular during the period with hyperthermic intraabdominal perfusion leading to an increase in the patients core temperature.
Results:
Nine out of ten patients had an increase in the SCA measurements during the HIPEC phase correlating the increase in temperature.
Conclusion:
SCA is unreliable to detect increased pain sensation during sudden perioperative temperature changes in adult patients.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...