Measuring aliphatic hydrocarbons in sediments by direct thermal desorption-gas chromatography-mass spectrometry:
Florence Portet-Koltalo1, Kévin Humbert2, Julie Cosme1
1COBRA Laboratory UMR CNRS 6014, Normandie University, UNIROUEN, 55 rue Saint Germain, Evreux 27000, France.
Abstract:
Direct sample introduction thermal desorption (TD) coupled to GC-MS was investigated for the analysis of paraffinic hydrocarbons (HCs) from polluted sediments. TD-GC-MS is sometimes used for analysing paraffinic HCs from atmospheric particles but rarely for their direct desorption from sediments. So, the new TD methodology, applied to sediments, required development, optimization and validation. A definitive screening experimental design was performed to discriminate the critical factors on TD efficiency, from model sediments containing various organic matter (OM) amounts. Low molecular weight HCs had extraction behaviours markedly different from high molecular ones (HMW-HCs), but a compromise was found using very few sediment amount (5 mg), high temperature rate (55 °C min-1) and final temperature (350 °C). Linear HCs (n-C10 to n-C40) could be quantified using the matrix-matched calibration method, with very low detection limits (3.8-13.4 ng). The amount of the overall paraffinic alkanes was also determined as a sum of unresolved components between predefined equivalent carbon ranges. The developed solventless methodology was compared to an optimized solvent microwave assisted extraction (MAE). Matrix effects could be higher for TD compared to MAE but it depended on sediment matrix. When matrix effect was strong, particularly on HMW-HCs signal depletion, a dilution with pure non-porous sand was favourable for accurate quantification. The sum of resolved and unresolved HCs gave comparable results between MAE and TD extractions, with an exception of alkanes greater than C30 which were less quantitatively extracted via TD. However, TD-GC-MS was more sensitive than MAE-GC-MS. So TD-GC-MS is useful for analyzing sediments containing a great range of paraffinic HCs (C9-C34) and it has the advantages of being fully automated, with few sample preparation and operator intervention, using very low amounts of solvent, and generating few wastes.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...