Related Experiment Video
Updated: Jun 28, 2025

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
Response Characteristics of Pressure-Sensitive Conductive Elastomer Sensors Using OFC Electrode with Triangular Wave
Takeru Katagiri1, Sogo Kodama2, Kotaro Kawahara3
1Department of Science of Technology Innovation, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka, Niigata 940-2188, Japan.
Abstract:
The sensor response of pressure-sensitive conductive elastomers using polymeric materials can be adjusted by altering the type and quantity of fillers used during manufacturing. Another method involves modifying the surface shape of the elastomer. This study investigates the sensor response by altering the surface shape of an electrode using a readily available pressure-sensitive conductive elastomer. By employing an oxygen-free copper electrode with a flat surface (with surface roughness parameters Ra = 0.064 μm and Rz = 0.564 μm) as a baseline, we examined the sensor system's characteristics. Electrodes were fabricated with triangular wave concavo-convex surfaces, featuring tip angles of 60, 90, and 120°. Improved sensor responses were observed with electrodes having tip angles of 60 and 90°. Additionally, even with varying conductive properties of elastomers, the conductance of the elastomer sensor increased similarly when using an electrode with a 90° tip angle. This study demonstrates the potential for expanding the applications of conductive elastomer sensors, highlighting the noteworthy improvement in sensor response and performance achieved by altering the surface shape of electrodes used with commercially available conductive elastomers.
More Related Videos
10:28Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
04:51Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
Published on: March 1, 2024
Related Concept Videos
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Design Example: Resistive Touchscreen
When a user touches the screen, the two layers make contact at a specific point known as the touchpoint. This contact reduces the resistance between...
Potentiometry: Membrane Electrodes
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...