Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Accuracy and Efficacy of Artificial Intelligence-Derived Automatic Measurements of Transthoracic Echocardiography in
Noriko Shiokawa1, Masaki Izumo2, Toshio Shimamura1
1Ultrasound Center, St. Marianna University Hospital, 2-16-1 Sugao, Miyamae-ku, Kawasaki 216-8511, Japan.
Abstract:
Background: Transthoracic echocardiography (TTE) is the gold standard modality for evaluating cardiac morphology, function, and hemodynamics in clinical practice. While artificial intelligence (AI) is expected to contribute to improved accuracy and is being applied clinically, its impact on daily clinical practice has not been fully evaluated. Methods: We retrospectively examined 30 consecutive patients who underwent AI-equipped TTE at a single institution. All patients underwent manual and automatic measurements of TTE parameters using the AI-equipped TTE. Measurements were performed by three sonographers with varying experience levels: beginner, intermediate, and expert. Results: A comparison between the manual and automatic measurements assessed by the experts showed extremely high agreement in the left ventricular (LV) filling velocities (E wave: r = 0.998, A wave: r = 0.996; both p < 0.001). The automated measurements of LV end-diastolic and end-systolic diameters were slightly smaller (-2.41 mm and -1.19 mm) than the manual measurements, although without significant differences, and both methods showing high agreement (r = 0.942 and 0.977, both p < 0.001). However, LV wall thickness showed low agreement between the automated and manual measurements (septum: r = 0.670, posterior: r = 0.561; both p < 0.01), with automated measurements tending to be larger. Regarding interobserver variabilities, statistically significant agreement was observed among the measurements of expert, intermediate, and beginner sonographers for all the measurements. In terms of measurement time, automatic measurement significantly reduced measurement time compared to manual measurement (p < 0.001). Conclusions: This preliminary study confirms the accuracy and efficacy of AI-equipped TTE in routine clinical practice. A multicenter study with a larger sample size is warranted.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
10:53Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...