Background:
Material-dependent parameters have an important impact on the efficiency of light polymerization. The present in vitro study aimed to investigate the influence of the increment thickness and shade of nano- and nanohybrid resin composites on the transmission of curing light.
Methods:
Three contemporary resin composites were evaluated: Tetric EvoCeram® (TEC); Venus Diamond® (VD); and Filtek Supreme XTE® (FS XTE). Light transmission (LT) was recorded in accordance with the sample thickness (0.5 to 2.7 mm) and the shade. Polymerized samples were irradiated for 10 s each using the high-power LED curing light Celalux 2 (1900 mW/cm2). LT was simultaneously recorded using the MARC Patient Simulator (MARC-PS).
Results:
LT was strongly influenced by the composite layer thickness. For 0.5 mm-thick samples, a mean power density of 735 mW/cm2 was recorded at the bottom side. For the 2.7 mm samples, a mean power density of 107 mW/cm2 was measured. Only LT was markedly reduced in the case of darker shades. From A1 to A4, LT decreased by 39.3% for FS XTE and 50.8% for TEC. Dentin shades of FS XTE and TEC (A2, A4) showed the lowest LT.
Conclusions:
The thickness and shade of resin composite increments strongly influences the transmission of curing light. More precise information about these parameters should be included in the manufacture manual.
More Related Videos
06:26Experimental Implementation of a New Composite Fabrication Method: Exposing Bare Fibers on the Composite Surface by the Soft Layer Method
Published on: October 6, 2017
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Light Acquisition
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Softwoods and Hardwoods
Wood Products
Glue-laminated wood, often referred to as glulam, combines multiple smaller pieces of dimensional lumber using adhesives to form a single, larger piece. Cross-laminated timber consists...