Related Experiment Video
Updated: Jun 28, 2025

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Performance Analysis of Ferronickel Slag-Ordinary Portland Cement Pervious Concrete
Zhongping Tang1,2, Hua Peng2, Pingbo Mei3
1Institute of Structural Material Failure and Strengthening Technology, Ningbo Polytechnic, 388 East Lushan Rd., Ningbo 315800, China.
Abstract:
It is unknown whether Ferronickel slag (FNS)-ordinary Portland cement (OPC)-based pervious concrete (FOPC) is feasible. To this end, a feasibility study was conducted on FOPC. Firstly, a detailed microscopic examination of the FNS powder was conducted, encompassing analyses of its particle size distribution, SEM, EDS, and chemical composition. These analyses aimed to establish the suitability of a composite of FNS and OPC as a composite cementitious material. Subsequent experimentation focused on evaluating the compressive strength of the composite paste material with varying mixed proportions, revealing a slight reduction in strength as the FNS substitution rate increased. Furthermore, the study designed eighteen different mix proportions of FOPC to investigate the key physical properties, including porosity, density, compressive strength, and the coefficient of permeability. Findings indicated that increases in the cementitious material proportion correlate with enhanced concrete strength, where the ratio of cementitious to aggregate increased by 6.7% and 16.5%, and the strength of FOPC increased by 10-13% and 30-50%, respectively. Conversely, a rise in the FNS substitution rate led to a reduction in compressive strength across different mix ratios. Additionally, the ratio of paste material to aggregate was found to significantly influence the permeability coefficient. These comprehensive performance evaluations suggest that incorporating FNS into OPC for pervious concrete applications is a feasible approach, offering valuable insights for the promotion of waste reuse and the advancement of energy conservation and emissions reduction efforts.
More Related Videos
Related Concept Videos
Types of Cement II
Portland Cement
Pozzolans
Fly ash is...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Ferrocement

