Related Experiment Video
Updated: Aug 4, 2026

Three Dimensional Vestibular Ocular Reflex Testing Using a Six Degrees of Freedom Motion Platform
Published on: May 23, 2013
Biomechanics Explains Variability of Response of Small Hypertropia to Graded Vertical Rectus Tenotomy
Chang Zoo Kim1, Seongjin Lim2, Joseph L Demer3
1From the Stein Eye Institute and Department of Ophthalmology, University of California, Los Angeles (C.K., S.L., J.L.D.), Los Angeles, California, USA; Department of Ophthalmology, College of Medicine, Kosin University (C.K.), Busan, Korea.
Purpose:
Small angle hypertropia in sagging eye syndrome is conveniently treated by graded vertical rectus tenotomy, yet an adjustable technique under topical anesthesia has been recommended because of variability of effect. We performed graded tenotomy in an experimental model to elucidate the reason for variability of response to this surgical procedure.
Design:
Experimental study.
Methods:
Thirty-two fresh bovine rectus musculotendon specimens were prepared including continuity with insertional sclera, and extending for a total 40 mm length to the proximal muscle bellies, and trimmed to 16 mm width. Specimens were anchored by the clamps at the scleral insertion and muscle belly ends within a physiological chamber. After preconditioning and elongation to 10% strain was imposed by a linear motor, tensile force was allowed to stabilize at a plateau state. Then 25%, 50%, 75%, 90%, and 100% marginal tenotomies were performed progressively as remnant forces were measured.
Results:
Tendon thickness averaged 0.29 ± 0.05 mm and width 19.71 ± 2.25 mm. On average, remnant force decreased linearly (R2 = 0.985) from 4.23 ± 1.34, 2.76 ± 0.88, 1.70 ± 0.73, 1.01 ± 0.49, 0.39 ± 0.10, and 0 N, at 0%, 25%, 50%, 75%, 90%, and 100% tenotomy. However, there was marked individual variability in effect among specimens, with coefficients of variation of 32%, 32%, 43%, 49%, and 27%, respectively.
Conclusion:
On average, there is a linear relationship between graded rectus tenotomy and percentage force reduction, but the effect among individual tendons is large, paralleling the reported variation in surgical effect. This explains and implies continued advisability of adjustable technique in this procedure.
Related Concept Videos
Upward Impending Motion
To better comprehend how a screw jack functions, consider the completely unraveled thread as a block in contact with the...
Normal and Tangetial Components: Problem Solving
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Transformation of Plane Stress
Influence of Earth's Curvature and Atmospheric Refraction on Leveling